Loading...
HomeMy WebLinkAboutI. Western States Engineering Anchor System 2019MINUTE MAN ANCHORS, INC. 305 WEST KING STREET EAST FLATROCK, NC 28726 PH: (800) 438-7277 ENGLNEERED TIE DOWN SYSTEM DESIGN & GENERAL NOTES DESIGN LOADS: ' WIND - 15 PSF (70 MPH EXPOSURE "C") CAC T-25 and COMPLIES WITH THE 2016 CBC Vult = 110 _MP_ _H EXP °C" AND THE 2015 IBC Vult = 115 MPH EXP °C' ' SOIL BEARING1500 PSF ' TIE DOWN STRAP 3150# WORKING LOAD • SEISMIC ZONE 4 CAC T-25 AND 2010 C.R.C. S5=1_5 Fa=1_4 Scs 1.41 Site Class D TIE DOWN STRAPS TO BE MIN. 1 114" WIDE x 0.035 THICKNESS ZINC PLATED AND MEET ASTM D-395391 EARTH AUGERS 3150# (tested to 4725# min) CROSS DRIVES (soil) ...1575# ( calculated, see Gen Note 4) CROSS DRIVES ( asphalt) ...1800# (tested to 3600#) asphalt min 2.5" thick CROSS DRIVES (solid rock )..3150# (tested to 4725# min) CONCRETE SLAB ANCHORS....3150# ( tested to 4725# min ) drill proper siie pilot hole min 4" from any edge GENERAL NOTES: 1. THE CHARTS SHOWN HEREIN ARE FOR THE REQUIRED NUMBER OF TIE DOWNS ON THE SIDES OF THE MANUFACTURED HOME. 2. TIE DOWNS ARE REQUIRED AT EACH CHASSIS BEAM, EACH END OF)EACH TRANSPORTABLE SECTION OF THE MANUFACTURED HOME AND CAN BE ANY OF THE TYPES SHOWN HEREIN. 3. COMBINATIONS OF THE DIFFERENT TYPES OF TIE DOWNS CAN BE USED. 4. IN THE EVENT AN EARTH AUGER CANNOT BE INSTALLED DUE TO AN OBSTRUCTION, USE OF CROSS DRIVE ANCHORS IS PERMITTED, PROVIDED (2) CROSS DRIVES ARE INSTALLED FOR EACH EARTH AUGER THAT CANNOT BE INSTALLED. 5. FOR ALL TIE DOWN INSTALLATIONS, THE MFG'D HOME CHASSIS MEMBERS ARE SHOWN AS "I" BEAMS. FOR ILLUSTRATION PURPOSES ONLY. CHASSIS BEAMS CAN ALSO BE "C" SHAPED OR "RFC" SHAPED. 6. END TIE DOWNS CAN BE LOCATED WITHIN 24" OF EITHER SIDE OF CHASSIS BEAM AXIS AS SHOWN. C` �I 18 MIN. 1 7. THE SIZES, TYPES, LENGTHS, ECT. OF MATERIAL SHOWN HEREIN ARE MINIMUM. LARGER, LONGER, HEAVIER MATERIALS SUPPLIED BY MINUTE -MAN PRODUCTS. MAY BE USED AT THE SAME SPACING & LOCATION SHOWN. 8. ALL PARTS ARE STAMPED MMA- WITH THE APPROPRIATE PART NUMBER. 9. THIS TIE DOWN SYSTEM CAN BE USED WITH 10' WIDE MANUFACTURED HOME SECTIONS WITH 100" CHASSIS CENTERS PROVIDED THE HEIGHT FROM GRADE TO THE BOTTOM OF THE CHASSIS BEAM DOES NOT EXCEED 19". 10. TIE DOWN STRAPS IN THE LONGITUDINAL OR TRANSVERSE DIRECTION CAN BE BOLTED TO THE HITCH ATTACHMENT PLATE THAT IS WELDED TO THE CHASSIS BEAM. ENGINEER APPROVAL SEE STATE APPROVAL PACIFIC CONSULTING ENGINEERS 2150 BELL AVE. SUITE 145 SACRAMENTO, CALIFORNIA 95838 PH: (916) 564-6028 ENGINEERED TIEOOWN SYSTEM 'APPROVED Approved 'ices not authorize or approve any omission or deviation !loin rsqutrer.:ents of applicable State laws and State n1 Califtrnia Departmr 1it • , w l : ..urly::unity Development 01‘.i" jty, 'ODES AND STANDARDS /, , ��..._-___._.._—._ ..._0ate '2-��1_/ L tS natured 14 ill(_ E./ in This Plan Approval Expires 2-i:1'3/i) DA. DRQ`. w d 1 \ i INSTALLATION INSTRUCTIONS FIRST CHECK FOR UNDERGROUND UTILITY LOCATION: EZDH EARTH AUGERS 1. SEE DETAIL THIS BOOKLET FOR INSTALLATION INSTRUCTIONS. EARTH AUGERS 1. INSTALL AUGERS INTO SOIL WITH CONSTANT DOWNWARD PRESSURE TO MINIMIZE SOIL DISTURBANCE LEAVING APPROX. 12" OF SHAFT EXPOSED. 2. INSTALL STABILIZER PLATE - DRIVE FLUSH WITH GROUND SURFACE. 3. COMPLETE TURNING AUGER INTO GROUND UNTIL AUGER HEAD IS FLUSH WITH GROUND SURFACE AND TOP OF STABILIZER PLATE. CROSS DRIVE ANCHORS 1. CROSS DRIVES ARE USED WHERE HARD ROCKY SOIL OCCURS. IF THE GROUND SURFACE IS OTHER THAN ROCK OR - MIN 2.5" ' ASPHALT, INSTALL MMA-SD2 STABILZER PLATE, OR PLACE 12"x12"x12" DEEP CONCRETE. CONCRETE SLAB ANCHORS 1. CONCRETE SLAB TO BE MINIMUM 3 1/2" THICK AND IN GOOD CONDITION. 2. MINIMUM SLAB AREA REQUIRED FOR EACH ANCHOR IS 28 SQ. FEET. 3. DRILL PROPER SIZE HOLE IN SLAB MINIMUM 4" FROM ANY EDGE. ALL APPLICATIONS 1. ATTACH STRAPS TO CHASSIS BEAM IN MANNER SHOWN. 2. INSERT STRAP THROUGH SPLIT NUT, CUT OFF EXCESS STRAP AND TIGHTEN UNTIL SNUG. THIS PLAN MAY BE USED FOR MANUFACTUED HOMES PLACES IN FEMA FLOOD HAZARD ZONES A, AE & AH, PROVIDED THE GROUND ANCHORS ARE THE MMA -650, 50" EARTH AUGERS. UNDER FLOOR VENTS AT THE PERIMETER SKIRTING SHALL BE PLACED WITH THE BOTTOM OF THE VENT MAX 12" ABOVE THE UNDER FLOOR GROUND SURFACE TIE DOWN LOCATIONS END TIE DOWNS SEE CHART SINGLE WIDE SIDE 11E DOWN - SEE CHART END TIE DOWNS END TIE DOWNS SEE CHART SEE CHART V DOUBLE WIDE SIDE TIE DOWN - TRIPLE WIDE EARTH AUGER - CROSS DRIVE ANCHORS CONCRETE SLAB ANCHORS MAX. LENGTH MFG'D HOME OF 32' 42' 52' 62' 73' M MFG D HOME F 32' 42' 52' 62' 73' M MFG'D HOME F 34' 42' 50' 59' 68' MAX. NO. OF SIDE TIE DOWNS 3 4 5 6 MAX. NO. OF SIDE TIE DOWNS 3 4 5 6 7 MAX. NO. OF SIDE TIE DOWNS 4 5 6 7 8 NOTE: IF OBSTRUCTIONS PRECLUDE THE PLACEMENT OF THE SIDE TIE DOWNS AT THE 2' LOCATION SHOWN SIDE TIE DOWNS AT 2'-0" FROM EACH END HAVE A TOLERANCE OF 1't MINUITE MAN PRODUCTS h.-18" MIN. LISTED BY: RADCO 3220 E. 59th Street Long Beach. CA 90805 LISTING NUMBER AT .1344 TIE DOWN SYSTEM TO BE IDENTIFIED BY A STICKER PLACED ON THE STEEL STRAPS MM -32 OR MMA -71 - STICKER TO CONTAIN THE FOLLOWING. MINIUTE MAN PRODUCTS ETS-119 RADCO Listing Number 1344 NOTE: TIE DOWN STRAPS AT THE CHASSIS BEAM ENDS (END TIE DOWNS) CAN BE ATTACHED TO A CHASSIS SUPPORT PIER WITH A PIER BOLT ON TOP. (SEE SKETCH ABOVE). END TIE DOWN W 0 (1 "I"BEAM SHOWN, SEE "C"&"RFC" CHASSIS FOR END TIE DOWN CONNECTIONS MMA34 FRAME TE SIDE TIE DOWN SPLIT BOLT AND NUT 0. _ 10'r NC4636, EZDH & MMA34 EARTH AUGER TIE DOWN DRILL 9/16" HOLE AT MID HEIGHT OF BEAM, INSTALL 1/2" A307 BOLT. 1/2H STEEL STRAP SEE "I"BEAM CHASSIS FOR TIE DOWN ANCHOR I"BEAM SHOWN, SEE "& RFC'CHASSIS FOR END TIE DOWN CONNECTIONS MMA34 FRAME TIE STABIUZER PLATE 0 DRILL 9/16" HOLE AT MID HEIGHT OF BEAM, INSTALL 1/2" A307 BOLT. 1/2H SIDE TIE DOWN -10' STEEL STRAP SEE"I"BEAM CHASSIS FOR TIE DOWN ANCHOR SPLIT BOLT AND NUT EARTH AUGER TIE DOWN "C" BEAM CHASSIS "RFC" BEAM CHASSIS INSTALLATION INSTRUCTIONS 1. THE DRIVE MACHINE IS STARTED AND THE ANCHOR IS TURNED INTO THE GROUND TO A POINT WHERE THE TOP (STABILIZER HEAD PLATE) IS FLUSH OR SLIGHTLY BELOW GROUND LEVEL. THIS INSURES THAT THE E -Z ANCHOR STABILIZER WILL BE AT ITS REQUIRED INSTALLATION POSITION. 2. FOR THE E -Z ANCHOR/STABILIZER TO ACHIEVE FULL POTENTIAL, INSTALL THE ANCHOR VERTICALLY WITH NO DEVIATION GREATER THAN 10 DEGREES. NOTE: A SLIGHTLY GREATER ANGLE MAY BE USED TO START THE ANCHOR TO AVOID CONTACT WITH THE HOME & STRAIGHTENED AS THE ANCHOR IS GROUND SET. THE SPLIT BOLT IS INSERTED, STRAP FASTENED, AND TIGHTENING ADJUSTMENT MADE. NOTE: WITH MACHINE INSTALLATION, A MINUTE -MAN ADAPTER DESIGNED TO FIT BOTH THE ANCHOR HEAD AND DRIVE MACHINE SHAFT IS AVAILABLE. INSTALLERS DO NOT NEED ADDITIONAL OR SPECIAL EQUIPMENT FOR E -Z ANCHOR INSTALLATION. MMA34 FRAME TIE #7002 7' STEEL STRAP WITH HOLE CONCRETE TIE DOWN CHASSIS CROSS DRIVE TIE DOWN " BEAM SHOWN, SEE C"& RFC"CHASSIS FOR END TE DOWN CONNECTIONS MMA34 FRAME TIE #7000 7' STEEL STRAP W/ BUCKLE SIDE TIE DOWN • ` STEEL • STRAP / SPLIT BOLT & NUT STABUZER PLATE 41, GROUND LINE #6005 SPLfT BOLT & NUT CROSS DRIVE ANCHOR CROSS DRIVE W/ STABILIZER W PLATE DETAIL FRAME CLIP YZ"x1" GRADE 5 BOLT & NUT WITH WASHER MMASD2 STABILIZER PLATE MMA -18 CONCRETE SLAB ANCHOR STABILIZATION PLATE WELDED TO ROD GUIDE & STRAP HEAD LOCKING CLIP HOME FRAME PIVOT CLIP MUST NOT VARY MORE THAN 10 DEG. FRO PERPENDICULAR TO BEAM. LOCKING CUP HAS 2-1/2" HOLES FOR USE ON 3" OR 4" FLANGES. MM 32 STEEL STRAP W/BUCKEL MMA -33 USE OUTSIDE HOLES FOR 31i" - 4" FLANGES N;41 t die '1"BOTTOM PLATE MMA -34 LONGITUDINAL FRAME TIE 4/ AND CLAMP (FOR WIND ZONE I) MMA -34 BOTTOM PLATE O0 O0 oO O0 MMA -71 STEEL STRAP W/CORNER TIE TOP PLATE O� O� 00 O0 Oo O0 USE INSIDE HOLES FOR 2" - 3" FLANGES 4- )"x1)c" GRADE 6 MACHINE BOLTS 8 -k2" HIGH STRENGTH WASHERS AZTEX ANCHOR MMA -35 & MMA -35S (swivel head) CROSS DRIVE ANCHOR CROSS DRIVE ANCHOR W/ 3/4"0x32" RODS W/ 23/32"0x30" RODS ❑ ❑ MMA-210JDH MMA-210PDH STABILIZER CAP COMPACTING DISK MMA SPLIT BOLT & NUT MMA -91 5/8 DIA MMA 71 CORNER TIE w/STRAP & RADIUS CLIP CONNECTED ONLY TO BOLT NEAREST TO ANCHOR LOCATION OF MODEL NO. 6" DIA STABILIZER CAP MMA 6 3/4 DH 4430 NU 3/4 MMA -92 3/4 DIA MMA -94 3/4 DIA MMA -650 3/4 DIA Y4"x2Y4" GRADE 5 BOLT & NUT ``rte 3/4"x32" DRIVE ROD. SOIL ANCHOR GW2 - SOIL ANCHOR w 3/4"x32" DRIVE ROD 4430 DH 3/4 DIA 32"AUGER ANCHOR 32"AUGER ANCHOR 36"AUGER ANCHOR 50"AUGER ANCHOR 30" AUGER ANCHOR TLW 10-05 W 0 0