HomeMy WebLinkAbout1.14 Geotechnical ReportH-R�XUMAR 5020 County Road 154
Glenwood Springs, CO 81601
Geotechnical Engineering I Engineering Geology Phone: (970) 945-7988
Materials Testing I Environmental Fax: (970) 945-8454
Email: hpkglenwood@kumarusa.com
Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, Summit County, Colorado
June 20, 2018
David Jones
6809 County Road 214
New Castle, Colorado 81647
drichmondjones @ gmail.com
Project No. 18-7-415
Subject: Observation of Excavation, Proposed Residence, 6809 County Road 214 (Peach
Valley Road), Garfield County, Colorado
Dear David:
As requested, a representative of H-P/Kumar observed the excavation at the subject site on June
19, 2018 to evaluate the soils exposed for foundation support. The findings of our observations
and recommendations for the foundation design are presented in this report. The services were
performed in accordance with our agreement for professional engineering services to you, dated
June 19, 2018.
The proposed residence will be a one story wood frame structure with a slab -on -grade floor.
Foundations were designed based on an assumed allowable soil bearing pressure of 1,500 psf.
At the time of our visit to the site, the foundation excavation had been cut in one level from 3 to
5 feet below the adjacent ground surface. The soils exposed in the bottom of the excavation
consisted of clayey sand and gravel with cobbles. The natural soils had been mostly covered
with 3/a inch screened rock in the excavation area. The results of a gradation analysis performed
on a sample of the clayey sand and gravel (minus 3 inch fraction) obtained from the site are
presented on Figure 1. Free water was observed in the excavation and the soils were moist to
very moist. The source of the water appears to be the nearby irrigation ditch located uphill of the
house site. We understand that it is planned to line this ditch later in the summer.
Considering the conditions exposed in the excavation and the nature of the proposed
construction, spread footings placed on the undisturbed natural soil designed for an allowable
soil bearing pressure of 1,500 psf can be used for support of the proposed residence. Footings
should be a minimum width of 16 inches for continuous walls and 2 feet for columns.
Groundwater seepage should be diverted and collected outside of footing areas. Loose disturbed
soils and mud in footing areas should then be removed and the bearing level extended down to
the undisturbed natural soils. Exterior footings should be provided with adequate soil cover
above their bearing elevations for frost protection. Continuous foundation walls should be
reinforced top and bottom to span local anomalies such as by assuming an unsupported length of
David Jones
June 20, 2018
Page 2
at least 10 feet. Foundation walls acting as retaining structures (if any) should also be designed
to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 50 pcf for on-
site soil as backfill. An underdrain can be provided around the foundation to prevent temporary
buildup of hydrostatic pressure. Structural fill placed within floor slab areas should consist of
compacted 3/4 inch screened rock or other suitable gravel soils (such as road base) compacted to
at least 95% of standard Proctor density at a moisture content near optimum. Backfill placed
around the structure should be compacted and the surface graded to prevent ponding within at
least 10 feet of the building.
We recommend below slab vapor retarders conform to at least the minimum requirements of
ASTM E1745 Class C material. Certain floor types are more sensitive to water vapor
transmission than others. For floor slabs bearing on angular gravel or where flooring system
sensitive to water vapor transmission are utilized, we recommend a vapor barrier be utilized
conforming to the minimum requirements of ASTM E1745 Class A material. The vapor retarder
should be installed in accordance with the manufacturers' recommendations and ASTM E1643.
The recommendations submitted in this letter are based on our observation of the soils exposed
within the foundation excavation and do not include subsurface exploration to evaluate the
subsurface conditions within the loaded depth of foundation influence. This study is based on
the assumption that soils beneath the footings have equal or better support than those exposed.
The risk of foundation movement may be greater than indicated in this report because of possible
variations in the subsurface conditions. In order to reveal the nature and extent of variations in
the subsurface conditions below the excavation, drilling would be required. It is possible the
data obtained by subsurface exploration could change the recommendations contained in this
letter. Our services do not include determining the presence, prevention or possibility of mold or
other biological contaminants (MOBC) developing in the future. If the client is concerned about
MOBC, then a professional in this special field of practice should be consulted.
If you have any questions or need further assistance, please call,our office.
Sincerely,
H -P:-,' KUMAR
Daniel E. Hardin, P
Rev. by: SLP
DEH/kac
P p /CF�
9�
;Q
24443 Z•
€\�0NAL
attachment Figure 1— Gradation Test Results
cc: Brad Jordan (brad jordanarchitect@gmail.com)
H-P45KUMAR
Project No. 18-7-415
HYDROMETER ANALYSIS
SIEVE ANALYSIS
TIME READINGS
U.S. STANDARD SERIES CLEAR SQUARE OPENINGS
100
24 NRS
45 MIN
7 NRS
15 MIN 60MIN 19MIN 4MIN 1MIN alloo
aloo &5D A40 930 & 6 AID as 44 3 S' 3/0 1 1/2* 3..a
t0
10
6020
70
30
60
40
SO
7
G
SO
40
60
30
70
20
s0
10
90
I
O
.. L _ _ _ _ _. _ . _.. __
_ 111 1
100
.001 .002 .005 .009 .019 .037 .075 .150 .300 1 .600 1.16 2.36 4.75 9.5 19 36.1 76.2 127
425 2.0 152
DIAMETER OF PARTICLES IN MILLIMETERS
200
CLAY TO SILT
SAND
I GRAVEL
COBBLES
FINE I MEDIUM 1COARSE1
FINE COARSE
GRAVEL 44 X SAND
39 X SILT AND CLAY 17 X
LIQUID LIMIT
PLASTICITY INDEX
SAMPLE OF: Clayey Sand and Gravel
FROM: South Side Footing Grade
These test results apply only to the
samples which were tested. The
testing report shall not be reproduced,
except in full, without the written
approval of Kumar 3 Associates, Inc.
Sieve analysis testing is performed In
accordance with ASTM D422, ASTM C136
and/or ASTM DII40.
18-7-415
H -R KUMAR
GRADATION TEST RESULTS