HomeMy WebLinkAbout1.09 General Application Materials_Part10TEP ROCKY MOUNTAIN LLCRECEPTION NO. 946446PARCEL NO. 240935200151
FYRWALD EXEMPTION PLAT LOT 3LAND SURVEY PLAT DEPOSIT NO. 312FRANK W & YONEKO McNEILPARCEL NO. 240935300128
FYRWALD EXEMPTION PLAT LOT 4LAND SURVEY PLAT DEPOSIT NO. 312GERALD GRUNKSA ET ALPARCEL NO. 240935300129
TEP ROCKY MOUNTAIN LLCRECEPTION NO. 946446PARCEL NO. 240935200151
FYRWALD EXEMPTION PLAT LOT 3LAND SURVEY PLAT DEPOSIT NO. 312FRANK W & YONEKO McNEILPARCEL NO. 240935300128
FYRWALD EXEMPTION PLAT LOT 4LAND SURVEY PLAT DEPOSIT NO. 312GERALD GRUNKSA ET ALPARCEL NO. 240935300129
LOD
SF
SP
SCL
VTC
SP
LOD
VTC
SF
CWA
PROPOSED
REROUTE OF EX.
2" IRRIGATION
LINE
CWA
STORMWATER
MANHOLE W/ GRATE
INLET TOP
RIM ELEV = 5528.49
VTC
CULVERT A
540' HDPE
18" DIA. @ 3.50%
INV: 5535.40
CULVERT D
34' HDPE
24" DIA. @ 2.90%
INV: 5442.91
CULVERT B
55' HDPE
36" DIA. @ 3.15%
INV: 5532.61
CULVERT D
34' HDPE
24" DIA. @ 3.41%
INV: 5583.52
5540
5550556
0
5570
5580559056005610562055305530
55505540
55305520551055005490
548
0
54
7
0
5
4
6
0
54505440
04/18/22
C01-0804/19/22MMLRDBISSUED FOR GARFIELD COUNTY REVIEW0-------------------------JOB NO.
SCALEDATEREVISIONSNO.DATEDWN.CHK.ELECTRIC POWER ENGINEERING, INC.12600 W. COLFAX AVE, STE. C500LAKEWOOD, CO 80215(303) 431-7895 www.neieng.com1691 300 COUNTY ROAD, PARACHUTE, CO1" = 200'
3704.002 PV CIVILGRADING & EROSION CONTROL OVERALL PLANHIGH MESANOTES
1.SITE CLEARING AND GRUBBING IS EXPECTED WITHIN SOLAR ARRAY PROJECT BOUNDARY AREA.
2.PROPOSED ACCESS ROADS WILL BE BUILT AT GRADE TO MAINTAIN EXISTING DRAINAGE PATTERNS.
3.SURVEY AND TOPOGRAPHY DATA TAKEN FROM "HIGH MESA-ALTA SURVEY -
ACQUISITION-ISSUED_04-20-2021" BY SGM INC.; DATED APRIL 20, 2021.
4.WETLANDS SHOWN AS PROVIDED IN THE ALTA SURVEY.
5.ELECTRICAL FEATURES ARE SHOWN HERE FOR ILLUSTRATIVE PURPOSES ONLY.
PRELIMINARY
NOT FOR CONSTRUCTION
FOR REVIEW & APPROVAL ONLY
SCALE:
200'100'0 200'400'600'
1"=200'
N
PROPOSED CONTOUR MINOR
PROPOSED CONTOUR MAJOR
PROPOSED LIMIT OF DISTURBANCE
PROPOSED ACCESS ROAD
PROPOSED SILT FENCE
PROPOSED CULVERT
PROPOSED SECURITY FENCE
PROPOSED FEATURES
PROPOSED LAYDOWN AREA
EROSION CONTROL
CONSTRUCTION ENTRANCE
PROPOSED INVERTER/ BESS PAD
PROPOSED SWITCHGEAR PAD
SEDIMENT CONTROL LOG
LEGEND:
EXISTING FEATURES
EROSION CONTROL KEYNOTES
INSTALL TEMPORARY SILT FENCE PER DETAIL ON
SHEET C01-12
INSTALL TEMPORARY VEHICLE TRACKING CONTROL
PER DETAIL ON SHEET C01-13
INSTALL CONCRETE WASHOUT PIT PER DETAIL ON
SHEET C01-13
INSTALL SEDIMENT CONTROL LOG PER DETAIL ON
SHEET C01-13
INSTALL STOCKPILE MANAGEMENT PER DETAIL ON
SHEET C01-13
SF
VTC
CWA
SCL
SP
SITE CUT/ FILL TABLE
CUT 1415.9 CY
FILL 5210.52 CY
NET 3758.62 CY (FILL)
EXISTING FENCE
EXISTING CONTOUR MINOR
EXISTING CONTOUR MAJOR
EXISTING ROAD EASEMENT
EXISTING FENCE
EXISTING UTILITY POLE
EXISTING OVERHEAD ELECTRIC
EXISTING LIMITS OF GAS PIPELINE
EXISTING PROPERTY LINE
EXISTING WETLANDS
EXISTING DITCH
EXISTING PROPERTY LINE
EXISTING WETLANDS
EXISTING DITCH
EXISTING DITCH SETBACK
EXISTING WETLANDS SETBACK
RIPRAP
EXISTING UNDERGROUND
WATER LINE
PROPOSED UNDERGROUND
WATER LINE
PROPOSED VISUAL SCREENING BERM
04/19/2022
SCL
VTC
SP
LOD
CW
SF
5450
5
4
6
0
5470
54805490
550055105
5
2
0
5530
5
5
3
0 55405550
CULVERT A
HDPE
18" DIA. @ 3.50%
INV: 5535.40
STORMWATER
MANHOLE W/ GRATE
INLET TOP
RIM ELEV = 5528.49
CULVERT D
34' HDPE
24" DIA. @ 2.90%
INV: 5442.91
VTC
544004/18/22
C01-0904/19/22 MML RDB ISSUED FOR GARFIELD COUNTY REVIEW0-- - ---- - ---- - ---- - ---- - --JOB NO.
SCALEDATEREVISIONSNO. DATEDWN. CHK.ELECTRIC POWER ENGINEERING, INC.12600 W. COLFAX AVE, STE. C500LAKEWOOD, CO 80215(303) 431-7895 www.neieng.com1691 300 COUNTY ROAD, PARACHUTE, CO1" = 100'
3704.002 PV CIVILGRADING & EROSION CONTROL PLANHIGH MESAKEY MAP
N.T.S.
KEY MAP
N.T.S.
NOTES
1. SITE CLEARING AND GRUBBING IS EXPECTED WITHIN SOLAR ARRAY PROJECT BOUNDARY AREA.
2. PROPOSED ACCESS ROADS WILL BE BUILT AT GRADE TO MAINTAIN EXISTING DRAINAGE PATTERNS.
3. SURVEY AND TOPOGRAPHY DATA TAKEN FROM "HIGH MESA-ALTA SURVEY -
ACQUISITION-ISSUED_04-20-2021" BY SGM INC.; DATED APRIL 20, 2021.
4. WETLANDS SHOWN AS PROVIDED IN THE ALTA SURVEY.
5. ELECTRICAL FEATURES ARE SHOWN HERE FOR ILLUSTRATIVE PURPOSES ONLY.
PRELIMINARY
NOT FOR CONSTRUCTION
FOR REVIEW & APPROVAL ONLY
SCALE:
100' 50' 0 100' 200' 300'
1"=100'
N
PROPOSED CONTOUR MINOR
PROPOSED CONTOUR MAJOR
PROPOSED LIMIT OF DISTURBANCE
PROPOSED ACCESS ROAD
PROPOSED SILT FENCE
PROPOSED CULVERT
PROPOSED SECURITY FENCE
PROPOSED FEATURES
PROPOSED LAYDOWN AREA
PROPOSED INVERTER/ BESS PAD
PROPOSED SWITCHGEAR PAD
LEGEND:
EXISTING FEATURES
EXISTING FENCE
EXISTING CONTOUR MINOR
EXISTING CONTOUR MAJOR
EXISTING ROAD EASEMENT
EXISTING FENCE
EXISTING UTILITY POLE
EXISTING OVERHEAD ELECTRIC
EXISTING LIMITS OF GAS PIPELINE
EXISTING PROPERTY LINE
EXISTING WETLANDS
EXISTING DITCH
EXISTING PROPERTY LINE
EXISTING WETLANDS
EXISTING DITCH
EXISTING DITCH SETBACK
EXISTING WETLANDS SETBACK
EROSION CONTROL KEYNOTES
INSTALL TEMPORARY SILT FENCE PER DETAIL ON
SHEET C01-12
INSTALL TEMPORARY VEHICLE TRACKING CONTROL
PER DETAIL ON SHEET C01-13
INSTALL CONCRETE WASHOUT PIT PER DETAIL ON
SHEET C01-13
INSTALL SEDIMENT CONTROL LOG PER DETAIL ON
SHEET C01-13
INSTALL STOCKPILE MANAGEMENT PER DETAIL ON
SHEET C01-13
SF
VTC
CWA
SCL
SP
EROSION CONTROL
CONSTRUCTION ENTRANCE
SEDIMENT CONTROL LOG
RIPRAP
EXISTING UNDERGROUND
WATER LINE
PROPOSED UNDERGROUND
WATER LINE
PROPOSED VISUAL SCREENING BERM
04/19/2022
LOD
SP
SCL
VTC
SP
VTC
CWA
REROUTE EX. 2" IRRIGATION LINE (FIELD VERIFY)
PROPOSED REROUTE OF EX. 2" IRRIGATION LINE
CWA
548
0
5490
550055105
5
2
0 553055405550
5530
5540
5550
556
0
5570
55805590560056105620CULVERT B
55' HDPE
36" DIA. @ 3.15%
INV: 5532.61
CULVERT C
33' HDPE
24" DIA. @ 3.41%
INV: 5583.52
STORMWATER
MANHOLE W/ GRATE
INLET TOP
RIM ELEV = 5528.49
CULVERT A
HDPE
18" DIA. @ 3.50%
INV: 5535.40
02/04/22
C01-1004/19/22 MML RDB ISSUED FOR GARFIELD COUNTY REVIEW0-- - ---- - ---- - ---- - ---- - --JOB NO.
SCALEDATEREVISIONSNO. DATEDWN. CHK.ELECTRIC POWER ENGINEERING, INC.12600 W. COLFAX AVE, STE. C500LAKEWOOD, CO 80215(303) 431-7895 www.neieng.com1691 300 COUNTY ROAD, PARACHUTE, CO1" = 100'
3704.002 PV CIVILGRADING & EROSION CONTROL PLANHIGH MESAKEY MAP
N.T.S.
NOTES
1. SITE CLEARING AND GRUBBING IS EXPECTED WITHIN SOLAR ARRAY PROJECT BOUNDARY AREA.
2. PROPOSED ACCESS ROADS WILL BE BUILT AT GRADE TO MAINTAIN EXISTING DRAINAGE PATTERNS.
3. SURVEY AND TOPOGRAPHY DATA TAKEN FROM "HIGH MESA-ALTA SURVEY -
ACQUISITION-ISSUED_04-20-2021" BY SGM INC.; DATED APRIL 20, 2021.
4. WETLANDS SHOWN AS PROVIDED IN THE ALTA SURVEY.
5. ELECTRICAL FEATURES ARE SHOWN HERE FOR ILLUSTRATIVE PURPOSES ONLY.
PRELIMINARY
NOT FOR CONSTRUCTION
FOR REVIEW & APPROVAL ONLY
PROPOSED CONTOUR MINOR
PROPOSED CONTOUR MAJOR
PROPOSED LIMIT OF DISTURBANCE
PROPOSED ACCESS ROAD
PROPOSED SILT FENCE
PROPOSED CULVERT
PROPOSED SECURITY FENCE
PROPOSED FEATURES
PROPOSED LAYDOWN AREA
PROPOSED INVERTER/ BESS PAD
PROPOSED SWITCHGEAR PAD
LEGEND:
EXISTING FEATURES
EXISTING FENCE
EXISTING CONTOUR MINOR
EXISTING CONTOUR MAJOR
EXISTING ROAD EASEMENT
EXISTING FENCE
EXISTING UTILITY POLE
EXISTING OVERHEAD ELECTRIC
EXISTING LIMITS OF GAS PIPELINE
EXISTING PROPERTY LINE
EXISTING WETLANDS
EXISTING DITCH
EXISTING PROPERTY LINE
EXISTING WETLANDS
EXISTING DITCH
EXISTING DITCH SETBACK
EXISTING WETLANDS SETBACK
EROSION CONTROL KEYNOTES
INSTALL TEMPORARY SILT FENCE PER DETAIL ON
SHEET C01-12
INSTALL TEMPORARY VEHICLE TRACKING CONTROL
PER DETAIL ON SHEET C01-13
INSTALL CONCRETE WASHOUT PIT PER DETAIL ON
SHEET C01-13
INSTALL SEDIMENT CONTROL LOG PER DETAIL ON
SHEET C01-13
INSTALL STOCKPILE MANAGEMENT PER DETAIL ON
SHEET C01-13
SF
VTC
CWA
SCL
SP
EROSION CONTROL
CONSTRUCTION ENTRANCE
SEDIMENT CONTROL LOG
RIPRAP
EXISTING UNDERGROUND
WATER LINE
PROPOSED UNDERGROUND
WATER LINE
PROPOSED VISUAL SCREENING BERM
SCALE:
100' 50' 0 100' 200' 300'
1"=100'
N
04/19/2022
FYRWALD EXEMPTION PLAT LOT 3LAND SURVEY PLAT DEPOSIT NO. 312FRANK W & YONEKO McNEILPARCEL NO. 240935300128
FYRWALD EXEMPTION PLAT LOT 4LAND SURVEY PLAT DEPOSIT NO. 312GERALD GRUNKSA ET ALPARCEL NO. 240935300129
FYRWALD EXEMPTION PLAT LOT 3LAND SURVEY PLAT DEPOSIT NO. 312FRANK W & YONEKO McNEILPARCEL NO. 240935300128
FYRWALD EXEMPTION PLAT LOT 4LAND SURVEY PLAT DEPOSIT NO. 312GERALD GRUNKSA ET ALPARCEL NO. 240935300129
LOD
SF
LOD
SF
PS
PSPS
PS
PS
04/18/22
C01-1104/19/22MMLRDBISSUED FOR GARFIELD COUNTY REVIEW0-------------------------JOB NO.
SCALEDATEREVISIONSNO.DATEDWN.CHK.ELECTRIC POWER ENGINEERING, INC.12600 W. COLFAX AVE, STE. C500LAKEWOOD, CO 80215(303) 431-7895 www.neieng.com1691 300 COUNTY ROAD, PARACHUTE, CO1" = 200'
3704.002 PV CIVILRESTORATION OVERALL PLANHIGH MESANOTES
1.PERMANENT STABILIZTION TO BE ACHIEVED BY GRASS SEED CONVERED WITH
STRAW AND OTHER MULCHES AND TACKIFIERS, ROLLED, EROSION CONTROL
PRODUCTS WITH GRASS SEED, OR BY HYDROSEEDING.
2.SURVEY AND TOPOGRAPHY DATA TAKEN FROM "HIGH MESA-ALTA
SURVEY - ACQUISITION-ISSUED_04-20-2021" BY SGM INC.; DATED
APRIL 20, 2021.
3.WETLANDS SHOWN AS PROVIDED IN THE ALTA SURVEY.
PRELIMINARY
NOT FOR CONSTRUCTION
FOR REVIEW & APPROVAL ONLY
SCALE:
200'100'0 200'400'600'
1"=200'
N
PROPOSED LIMIT OF DISTURBANCE
PROPOSED ACCESS ROAD
PROPOSED SILT FENCE
PROPOSED CULVERT
PROPOSED SECURITY FENCE
PROPOSED FEATURES
PROPOSED LAYDOWN AREA
EROSION CONTROL
PERMANENT SEEDING
PROPOSED INVERTER/ BESS PAD
PROPOSED SWITCHGEAR PAD
LEGEND:
EXISTING FEATURES
EROSION CONTROL KEY NOTES
SILT FENCE
LIMIT OF DISTURBANCE
PERMANENT SEEDING
SF
LOD
PS
EXISTING FENCE
EXISTING CONTOUR MINOR
EXISTING CONTOUR MAJOR
EXISTING ROAD EASEMENT
EXISTING FENCE
EXISTING UTILITY POLE
EXISTING OVERHEAD ELECTRIC
EXISTING LIMITS OF GAS PIPELINE
EXISTING UNDERGROUND
WATER LINE
EXISTING PROPERTY LINE
EXISTING WETLANDS
EXISTING DITCH
EXISTING PROPERTY LINE
EXISTING WETLANDS
EXISTING DITCH
EXISTING DITCH SETBACK
EXISTING WETLANDS SETBACK
RIPRAP
PERMANENT SEEDING MIX
PROPOSED UNDERGROUND
WATER LINE
PROPOSED VISUAL SCREENING BERM
04/19/2022
04/18/22
C01-1204/19/22MMLRDBISSUED FOR GARFIELD COUNTY REVIEW0-------------------------JOB NO.
SCALEDATEREVISIONSNO.DATEDWN.CHK.ELECTRIC POWER ENGINEERING, INC.12600 W. COLFAX AVE, STE. C500LAKEWOOD, CO 80215(303) 431-7895 www.neieng.com1691 300 COUNTY ROAD, PARACHUTE, CO-
3704.002 CIVILSITE DETAILSHIGH MESA-1
MINIMUM ULTRAVIOLET STABILITY
MINIMUM GRAB TENSILE STRENGTH
IN THE MACHINE DIRECTION
MINIMUM GRAB TENSILE STRENGTH
IN THE CROSS MACHINE DIRECTION
MAXIMUM APPARENT OPENING SIZE
EQUIVALENT STANDARD SIEVE
MINIMUM PERMITTIVITY
ASTM D 4355 70%
ASTM D 4491 0.05 SEC
ASTM D 4751 NO. 30
100 LBS.
120 LBS.
ASTM D 4632
ASTM D 4632
VALUE *METHOD
MAXIMUM APPARENT OPENING SIZE
IN THE CROSS MACHINE DIRECTION
MINIMUM GRAB TENSILE STRENGTH
IN THE MACHINE DIRECTION
MINIMUM GRAB TENSILE STRENGTH
TEST REQUIREMENT
-1
MAXIMUM PERMITTIVITY ASTM D 4491 0.135 SECOR 10 gpm/sq ft at 50 mm
constant head.
MINIMUM SPECIFIED VALUES.)
THE AVERAGE OF MINIMUM TEST RESULTS ON ANY ROLL IN A LOT SHOULD MEET OR EXCEED THE
* ALL NUMERICAL VALUES REPRESENT MINIMUM/MAXIMUM AVERAGE ROLL VALUES. (FOR EXAMPLE,
PERCENTAGE OF STRENGTH RETAINED
AFTER 500 HOURS OF EXPOSURE
NOTE:
1.THE GEOTEXTILE FABRIC SHALL BE PLACED IN THE EXCAVATED TRENCH, BACKFILLED, AND COMPACTED TO THE
EXISTING GROUND SURFACE.
2.WOODEN SUPPORT STAKES SHALL BE A MINIMUM DIMENSION OF 1-1/8" x 1-1/8" AIR OR KILN DRIED OF HICKORY
OR OAK AND 4 FEET LONG. STEEL POSTS SHALL BE STUDDED "TEE" OR "U" TYPE WITH A MINIMUM WEIGHT OF 1.3
POUNDS PER LINEAL FOOT AND 5 FEET LONG. POST SPACING SHALL BE A MAXIMUM OF 8 FEET FOR WOVEN
FABRIC AND 3 FEET FOR NON-WOVEN FABRIC.
3.THE GEOTEXTILE FABRIC SHALL BE ATTACHED DIRECTLY TO THE UPSLOPE SIDE OF WOODEN POSTS WITH 0.5
INCH STAPLES IN AT LEAST 3 PLACES, OR WITH WOODEN LATH AND NAILS. ATTACHMENT TO STEEL POSTS WILL
BE BY WIRE FASTENERS OR 50 POUND PLASTIC TIE STRAPS ON THE UPSLOPE SIDE.
4.THE GEOTEXTILE FABRIC SHALL CONSIST OF EITHER WOVEN OR NON-WOVEN POLYESTER, POLYPROPYLENE,
STABILIZED NYLON, POLYETHYLENE, OR POLYVINYLIDENE CHLORIDE. NON-WOVEN FABRIC MAY BE NEEDLE
PUNCHED, HEAT BONDED, RESIN BONDED, OR COMBINATIONS THEREOF. ALL FABRIC SHALL MEET THE
FOLLOWING REQUIREMENTS:
TYPICAL SECTION
EXISTING SOIL18" MIN.
6"
GEOTEXTILE FABRIC
SEE NOTE 4 FILL SLOPE
TOE ANCHOR
8'-0" MIN.
COMPACTED BACKFILL
6"
FLOW DIRECTION
FLOW DIRECTIONGEOTEXTILE FABRIC
WOOD POSTSTAPLE ALL AROUNDSTAPLE ALL AROUND
SUPPORT STAKE
SEE NOTE 2
*MAINTENANCE*
1.INSPECT ROLLED EROSION CONTROL PRODUCTS AT
LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH
OR GREATER) RAIN FALL EVENT REPAIR IMMEDIATELY.
2.GOOD CONTACT WITH THE GROUND MUST BE
MAINTAINED, AND EROSION MUST NOT OCCUR BENEATH
THE RECP. ANY AREAS OF THE RECP THAT ARE
DAMAGED OR NOT IN CLOSE CONTACT WITH THE
GROUND SHALL BE REPAIRED AND STAPLED.
3.CHECK FOR GENERAL SIGNS OF EROSION, INCLUDING
VOIDS BENEATH THE MAT. IF VOIDS ARE APPARENT, FILL
THE VOID WITH SUITABLE SOIL AND REPLACE THE
EROSION CONTROL BLANKET, FOLLOWING THE
APPROPRIATE STAKING PATTERN.
4.CHECK FOR DAMAGED OR LOOSE STAKES AND SECURE
LOOSE PORTIONS OF THE BLANKET.
5.IF EROSION OCCURS DUE TO POORLY CONTROLLED
DRAINAGE, THE PROBLEM SHALL BE FIXED AND THE
ERODED AREA PROTECTED.
6.MONITOR AND REPAIR THE RECP AS NECESSARY UNTIL
GROUND COVER IS ESTABLISHED.
3
8 4
5
2
7
6
1
* HORIZONTAL STAPLE SPACING SHOULD BE ALTERED
IF NECESSARY TO ALLOW STAPLES TO SECURE THE
CRITICAL POINTS ALONG THE CHANNEL SURFACE.
** IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE
OR STAKE LENGTHS GREATER THAN 6" (15 CM) MAY
BE NECESSARY TO PROPERLY ANCHOR THE BLANKETS.
A. OVERLAPS AND SEAMS
B. PROJECTED WATER LINE
C. CHANNEL BOTTOM/SIDE
SLOPE VERTICES
CRITICAL POINTS6"(15CM)4"-6"
(10CM-15CM)
12"
(30CM)
6"
(15CM)6"(15CM)6"(15CM)4"
(10CM)4"(10CM)2"-5"
(5CM-12.5CM)
C
BA
B
C
A
NOTES:
1.INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS.
2.IN LOOSE SOIL CONDITIONS THE USE OF STAPLE OR STAKE
LENGTHS GREATER THAN 6" (15CM) MAY BE NECESSARY TO
PROPERLY SECURE THE BLANKETS.
2
4
5
3B
1
3A
SLOPE INSTALLATION
2"-5"
(5CM-12.5CM)12"
(30CM)6"(15CM)6"
(15CM)
3"
(7.5CM)
NOTES:
1.INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
2.IN LOOSE SOIL CONDITIONS THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6" (15CM) MAY
BE NECESSARY TO PROPERLY SECURE THE BLANKETS.
1.PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING ANY NECESSARY APPLICATION OF LIME,
FERTILIZER, AND SEED.
2.BEGIN AT THE TOP OF THE SLOPE BY ANCHORING THE BLANKET IN A 6" (15CM) DEEP X 6" (15CM)
WIDE TRENCH WITH APPROXIMATELY 12" (30CM) OF BLANKET EXTENDED BEYOND THE UP-SLOPE
PORTION OF THE TRENCH. ANCHOR THE BLANKET WITH A ROW OF STAPLES/STAKES
APPROXIMATELY 12" (30CM) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE
TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" (30CM)
PORTION OF BLANKET BACK OVER SEED AND COMPACTED SOIL. SECURE BLANKET OVER
COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" (30CM) APART
ACROSS THE WIDTH OF THE BLANKET.
3.ROLL THE BLANKETS (A.) DOWN OR (B.) HORIZONTALLY ACROSS THE SLOPE. BLANKETS WILL
UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL BLANKETS MUST BE SECURELY
FASTENED TO SOIL SURFACE BY PLACING STAPLES/ STAKES IN APPROPRIATE LOCATIONS AS
SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING OPTIONAL DOT SYSTEM, STAPLES/STAKES
SHOULD BE PLACED THROUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE
APPROPRIATE STAPLE PATTERN.
4.THE EDGES OF PARALLEL BLANKETS MUST BE STAPLED WITH APPROXIMATELY 2"-5" (5CM-12.5CM)
OVERLAP DEPENDING ON BLANKET TYPE. TO ENSURE PROPER SEAM ALIGNMENT, PLACE THE EDGE
OF THE OVERLAPPING BLANKET (BLANKET BEING INSTALLED ON TOP) EVEN WITH THE COLORED
SEAM STITCH ON THE PREVIOUSLY INSTALLED BLANKET.
5.CONSECUTIVE BLANKETS SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END (SHINGLE
STYLE) WITH AN APPROXIMATE 3" (7.5CM) OVERLAP. STAPLE THROUGH OVERLAPPED AREA,
APPROXIMATELY 12" (30CM) APART ACROSS ENTIRE BLANKET WIDTH.
SLOPE INSTALLATION
CHANNEL INSTALLATION
3
NTS
SILT FENCE INSTALLATION
C01-12
2
NTS
ROLLED EROSION CONTROL PRODUCT INSTALLATION
C01-12
PLAN VIEW
PIPE NOTES:
1) L = LENGTH OF THE RIPRAP APRON.
2) L₂ = RIPRAP TO BE INSTALLED UNDERNEATH 1/3 THE
LENGTH OF FLARED END SECTION (FES).
3) d = 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT
LESS THAN 6 INCHES.
4) IN A WELL-DEFINED CHANNEL EXTEND THE APRON UP THE
CHANNEL BANKS TO AN ELEVATION OF 6 INCHES ABOVE
THE MAXIMUM TAILWATER DEPTH OR TO THE TOP OF THE
BANK, WHICHEVER IS LESS.
5) A FILTER BLANKET OR FILTER FABRIC SHOULD BE
INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION.
RIPRAP
APRON
SECTION 'A-A'
FILTER
FABRIC
d
L
PIPE
L₂
1
1SEE NOTE 4
FES
FES
4
NTS
PIPE OUTLET TO WELL-DEFINED CHANNEL
C01-12
LC
10'1:11:
1
4:1 SLOPE TO
EXISTING
GROUND
4:1 SLOPE TO
EXISTING
GROUND
2% SLOPE (TYP), MIN 1%EDGE OF GRAVELEDGE OF GRAVELPROPERLY COMPACTED AGGREGATE BASE
COMPACTED SUBGRADE
GEOTEXTILE SEPARATION FABRIC (MIRAFI 140N OR
EQUAL)
10'
6" MIN
NOTES:
1.4:1 MAXIMUM SLOPE FROM EDGE OF GRAVEL TO EXISTING GROUND.
2.AGGREGATE BASE COMPACTED TO A MINIMUM OF 95% OF THE SOIL'S MODIFIED
PROCTOR MAXIMUM DRY DENSITY.
3.AGGREGATE BASE COURSE SHOULD CONSIST OF A BLEND OF SAND AND GRAVEL
WHICH MEETS COLORADO DEPARTMENT OF TRANSPORTATION (CDOT) CLASS 5 OR 6
SPECIFICATIONS
4.SUBGRADE TO BE A MINIMUM 12-INCHES OF SCRIFIED, MOISTURE CONDITIONS, AND
RECOMPACTED SOIL.
5.ROAD GRADES ARE TYPICALLY INTENDED TO MATCH ADJACENT GRADE ALLOWING
DRAINAGE TO SHEET FLOW ON AND OFF ROADS EVENLY. FIELD ADJUST ROAD GRADES
OR DITCHE LOCATIONS AS NECESSARY TO PREVENT RUNOFF FROM CONCENTRATING
ALONG ROAD EDGES CAUSING EROSION.
6.ROADS SHALL HAVE 2" OF AGGREGATE BASE ADDED EVERY 5 YEARS, OR AS NEEDED TO
MAINTAIN MINIMUM DEPTH. ROADS SHALL UNDERGO SEMI-ANNUAL MAINTENANCE.
2% SLOPE (TYP), MIN 1%
1
NTS
20 FT WIDTH SOLAR ACCESS ROAD DETAIL
C01-12
NOTES:
1.EXCAVATE TO 4 INCHES BELOW THE PROPOSED PIPE ELEVATION.
2.PROVIDE 4 INCHES STONE BEDDING AND 4 INCHES STONE BACKFILL.
3.WHERE BELL AND SPIGOT PIPE IS USED, PROVIDE RECESSES TO RECEIVE PIPE BELL.
4.UNDERCUT UNSUITABLE MATERIAL AS DIRECTED BY THE ENGINEER AND BACKFILL WITH STONE OR
OTHER APPROVED MATERIAL.
5.WHERE NECESSARY, TEMPORARILY DIVERT SURFACE WATER TO MAINTAIN A DRY CONDITION IN THE
PIPE FOUNDATION. DIRECT THIS TEMPORARY FLOW INTO SUITABLE EROSION CONTROL DEVICES.
BACKFILL INITIAL LIFT: 12"MAX. NON TRAFFIC AREAS:12" MAX. LIFTS TRAFFICAREAS: 6" MAX. LIFTSCOMPACTION: 95% MAX.DRY DENSITY (STANDARDPROCTOR)
NO. 5, 57, OR 67 STONE
12" BED OF COMPACTED CRUSHER RUN
5
NTS
CULVERT CROSSING FILL AND COVER
C01-12
04/19/2022