Loading...
HomeMy WebLinkAbout1.01 Grading, Drainage, and Erosion Control PlanX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 10 0 - Y R 100 - Y R 100 - Y R 100 - Y R 100- Y R 100-YR 1 0 0 - Y R 100-YR SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S L S L S L S L S L S L S L ET C ET C ET C ET C ET C ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ET C ET C ET C ET C ET C ET C G G G G G G G G G G G MAIN LEVEL FF = 6265.00 GARAGE FF = 6265.00 WOOD SHOP FF = 6265.00 GB 2. 0 % HP GB 62 6 4 > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > >>>>> > > > > > >>>> 6 2 6 4 AMENDED BUILDING ENVELOPE, TYP. PROPERTY LINE, TYP. WHITE RESIDENCE LOT 12 TBD ST. FINNBAR FARM ROAD 2.865 Ac.± 16' S UG 2+0 0 2+ 8 6 P C : 2 + 0 5 . 0 4 PT: 2+25.87 EP: 2+86.38 62 6 4 6263 6263 6264 6264 62 6 2 62 6 3 6263 6 2 6 3 626 2 62 6 4 6264 62 6 4 6264 6 2 6 2 > > > > > > > > > > > > > > > > >>>>> > > > > > > 626 4 6 2 6 3 6 2 6 2 6 2 6 4 62 6 3 6263 6264 6 2 6 3 L =1 5 7 .8 1',R =1 3 0 .0 0 ' Δ =6 9 .5 5 N2 0 ° 2 4 ' 3 9 " E 10 . 2 6 ' S1 5 ° 3 7 ' 3 2 " W 25 5 . 9 1 ' S0 ° 0 3 ' 1 2 " W 15 3 . 5 7 ' 6263 N1 5 ° 3 7 ' 3 2 " E 15 0 . 3 3 ' S84° 09' 08"W 123.32' S55° 4 1 ' 0 9 " W 13.60 ' ORIGINAL BUILDING ENVELOPE, TYP. 40' 6 2 6 3 6 2 6 4 62 6 3 6 2 6 2 6 2 6 3 6 2 6 2 BUILDING OUTLINE PER KA DESIGNWORKS 12.6.21, TYP. ROOF OUTLINE, TYP. BUILDING OUTLINE PER KA DESIGNWORKS 12.6.21, TYP. ROOF OUTLINE, TYP. PROPERTY LINE, TYP. BENCHMARK, PIN & CAP LS 19598, EL. = 6262.68 ST . F I N N B A R F A R M R O A D ORIGINAL BUILDING ENVELOPE, TYP. 100 YEAR FLOODPLAIN & FLOODWAY LIMITS, REC. NO. 573741 6 2 6 4 #105 6263.23' #106 6263.44' #107 6263.80' #108 6264.17' #121 6263.11' #122 6263.32' #123 6263.00' #124 6263.39' #125 6263.78' #126 6263.31' #127 6263.30' #1286263.30' #129 6264.41' #130 6264.14' #131 6264.20' #132 6264.36'#133 6264.33' #134 6264.30' #135 6264.21' #136 6264.14' #137 6264.03' #138 6264.03' #139 6265.00' #140 6265.00' #1416264.69' #142 6264.55' #143 6264.48'#144 6264.44' #145 6263.64' #146 6263.24' #147 6264.02' #148 6263.60'#149 6263.90' #150 6263.72' #151 6264.32' #152 6264.49'#153 6264.46' #154 0.00' #155 0.00' #156 0.00'#157 0.00' #158 0.00' #159 0.00' #160 6263.00' #1616262.81' #162 6262.54' #163 6262.24' #1646262.00' S1 ° 1 1 ' 5 4 " E 6 0 . 5 1 ' R=24.00' L=20.83' R=18.00' L=28.25' 1 7 . 4 9 ' R=30.00' L=25.31' R=20.00' L=18.61' R = 2 5 . 0 0 ' L = 9 0 . 7 1' R=12.00' L=10.44' 2.84'R=12 .0 0 'L=3 .9 1'9.10' R =6.00' L =7.47' 5. 7 6 ' 13 . 4 7 ' R= 4. 0 0 ' L=6. 2 8 ' 3.21' R =6 .0 0 ' L =6.6 1 ' N88° 47' 34"E 26.75' S1 ° 1 2 ' 2 6 " E 4 8 . 5 1 ' 65. 0 0 65.0 0 65. 0 0 64. 9 0 64. 7 4 64. 5 64. 5 64. 5 64.5 64.5 65. 0 0 64. 5 64. 5 64. 5 65. 0 0 64.5 80 LF 6" ADS-N12 @ 1.0% RIM EL. 63.8 INV. EL. 62.3 65.0 0 64.9 2 64. 9 2 64. 8 4 64.8 4 64.5 64. 8 4 64. 5 6264 6264 62 6 4 > > > > > > > > > 62 6 4 6264 64. 5 65. 0 0 65. 0 0 65. 0 0 64.7 8 64.3 2 64.6 3 64. 8 8 64.5 ROOF OUTLINE, TYP. 64.5 64.5 3 64.5 64. 5 2.5% 2.2% 2.5% 2% S C F S C F S C F S C F S C F S C F S C F S C F S C F S C F S C F S C F S C F SCF SCF SCF SC F SC F SC F SC F SC F S C F S C F INV. EL. 61.50 6 2 6 2 > > > > GM G G G G G G G G G G G G G G G G G G G G G G 2. 2 8 % ETC ETC ET C ET C ET C ET C ET C ET C ET C 64.5 E T C E T C E T C E T C E T C E T C ET C ET C ET C ET C ET C ET C ET C ET C ET C ET C ET C ETC ETC ETC ETC ETC ETC ETC ETC ETC ET C ET C ET C ET C ET C ET C ET C ET C SL SL SL SL SL SL SL SL SL SL SL SL SL SL C/O C/O EDGE OF EXISTING ASPHALT, TYP. EXISTING GAS MARKER EXISTING ELECTRIC TRANSFORMER AND TELEPHONE RISERS 5 5 5 6 7 9 10 10 11 12 12 12 12 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 15 15 15 15 15 15 WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS W S W S W S W S W S W S W S W S W S 16 17 18 20 21 21 21 22 22 23 23 24 6 263 626 4 6263 6264 6263 6264 19 #165 6262.30' #166 6261.50' #167 6264.00' #168 6263.63' #169 6263.36' #170 6263.00' #171 6262.69' #172 6262.32' #173 6262.00' 10a (LOCATED 40'± OFF SHEET) 10a LP 12 (LOCATED 60'± OFF SHEET) 10 10 23 00 10'20' Scale: 1" = 10' NORTH By Re v i s i o n No . Da t e 923 Cooper Ave., Ste. 201 Glenwood Springs, CO 81601 (T) 970.945.5252 www.bu-inc.com Engineer or Surveyor Seal Sheet Client Information: PROJECT NO. File Name: Designer: Drafter: Date: N: \ P R O J E C T S \ 2 0 2 1 \ 2 1 0 3 1 - L o t 1 2 S t . F i n n b a r F a r m s \ d w g \ S P - 0 2 2 1 0 3 1 L 1 2 F i n n b a r . d w g 4/ 4 / 2 0 2 2 3 : 4 4 P M Subsurface Utility Engineering (SUE) Required Project: If "Yes", SUE Certification by: Firm: Job #: Date: 9.8.7.6.5.4.3.2. 11/23/21 BUI PAH sp-02 21031 l12 finnbar.dwg 21031 619 546-0006 SAN DIEGO, CA 92101 ---- SCOTT WHITE GA R F I E L D C O U N T Y , C O L O R A D O 1. Pe r m i t 4 / 4 / 2 2 Si t e , G r a d i n g , D r a i n a g e a n d E r o s i o n C o n t r o l P l a n Wh i t e R e s i d e n c e , L o t 1 2 , S t . F i n n b a r F a r m S u b d i v . C1 ### ###### ###### ###### MATCH TO SHEET C2 1 2 3 4 5 6 8 10 11 7 12 9 14 15 16 17 18 19 20 FLAGNOTES: MATCH TO EXISTING EDGE OF ROADWAY. INSTALL 12" STORM DRAIN. PROVIDE END WALLS AND WING WALLS CONSTRUCTED WITH STONE TO MATCH BUILDING MATERIALS, OR FLARED END SECTIONS. REGRADE PORTION OF ROADSIDE DITCH AS NECESSARY TO ENABLE NEW CULVERT TO MAINTAIN 12" OF COVER AT THE DRIVEWAY. INSTALL NORTH AMERICAN GREEN SC250 EROSION FABRIC IN DISTURBED PORTION OF DITCH. TRANSITION FROM ROADWAY GRADE INTO 2% CROSS SLOPE DRAINING TOWARD THE WEST IN THE FIRST 20 FEET OF DRIVEWAY. PROPOSED ASPHALT DRIVEWAY, AUTO-COURT AND CONCRETE WALKWAYS. SEE DRIVEWAY DETAIL ON SHEET C3. INSTALL 8" NYLOPLAST DRAINAGE BASIN & DOME INLET. SEE DETAIL. PROTECT CULVERT WHEN CONSTRUCTING IMPROVEMENTS ABOVE FROM MATERIAL AND EQUIPMENT, TYP. CLEAN DITCH AS NECESSARY TO MAINTAIN DRAINAGE FLOWS. CONFIRM FEEDER DITCH HAS BEEN BLOCKED AND FILLED AT THE SOURCE, AND IS OUT OF SERVICE. PROVIDE DRAINAGE SWALE AND EXTEND AS NECESSARY TO DAYLIGHT, SEE DETAIL. PROVIDE DRAINAGE SWALE AND EXTEND TO ROADSIDE DITCH. REMOVE FENCE AS NECESSARY. SLOPE PATIOS AND DECKS AT 2% MIN. AWAY FROM THE STRUCTURE. GRADE AROUND THE PERIMETER OF BUILDING AS NECESSARY 10% FOR 5-FEET MIN. (10 FT. WHERE POSSIBLE) IN UNPAVED AREA TO ENSURE PROPER DRAINAGE AWAY FROM THE FOUNDATION. SHAPE TO DRAIN AWAY FROM THE HOUSE SUCH THAT ANY DRAINAGE CAN SHEET FLOW TO THE EXTERIOR DRAINAGE SWALES OR SHEET DOWNHILL. IT WILL BE IMPORTANT TO CONSTRUCT AND DIRECT SURFACE DRAINAGE AWAY FROM BUILDING, WALKS AND WALLS TO THE OUTLET SWALE OR DRIVEWAY. VERIFY DRAINAGE AND SWALE INTEGRITY ON A REGULAR BASIS. THERE WAS A WELL, BUT NO WATER SERVICE SHOWN ON THE OLD HCE FIELD SURVEY. [ST. FINNBAR FARM SUBDIVISION - LOT 12, BY HIGH COUNTRY ENGINEERING, INC. (HCE) JOB NO. 89074-09 DATED 2/5/01]. CONFIRM IF WELL EXISTS. IF SO, CONNECT AND EXTEND NEW WATER SERVICE TO MECHANICAL ROOM. MAINTAIN COVER OVER NEW SERVICE PER DISTRICT REGULATIONS. LOCATE EXISTING SEWER STUB, (AS SHOWN ON THE HCE SURVEY REFERENCED ABOVE), CONFIRM LOCATION AND INVERT PRIOR TO CONSTRUCTION FOR ABILITY TO SERVICE BY GRAVITY, OR WHETHER A PUMP MAY BE REQUIRED, AND CONNECTION WITH THE METRO DISTRICT, CONNECT AND EXTEND NEW SEWER SERVICE TO MECHANICAL ROOM. MAINTAIN COVER OVER NEW SERVICE PER DISTRICT REGULATIONS. INSTALL CLEANOUTS AT HOUSE EXTERIOR AND ALL BEND LOCATIONS. ASSUMED LOCATION OF GAS SERVICE. (PER GAS MARKER IN THE FIELD), LOCATE & INSTALL GAS SERVICE FROM EXISTING SERVICE STUB TO MECHANICAL ROOM. MAINTAIN COVER & SEPARATION OVER & AROUND NEW SERVICE PER UTILITY REGULATIONS. ALTERNATE 1). ELECTRIC, TELEPHONE & CABLE TV SERVICES ARE AS SHOWN ON THE HCE SURVEY REFERENCED ABOVE. POTHOLE NEAR THE SOUTH EDGE OF THE ROAD TO SEE IF THESE SERVICES EXIST. IF SO, EXTEND SERVICES TO UTILITY METERS. MAINTAIN COVER & CLEARANCES BETWEEN/OVER NEW SERVICES PER UTILITY REGULATIONS. ALTERNATE 2). IF THE SHALLOW UTILITIES DO NOT EXIST PER ALTERNATE 1, EXTEND NEW SERVICES FROM THE EXISTING TRANSFORMER AND UTILITY RISERS TO UTILITY METERS. MAINTAIN COVER & CLEARANCES BETWEEN/OVER NEW SERVICES PER UTILITY REGULATIONS. EROSION LOGS, TYP. PER DETAIL ON SHEET C2. SEDIMENT CONTROL FENCE, TYP. PER DETAIL ON SHEET C2. PROTECT UTILITY SERVICES AND PIPES WHEN CONSTRUCTING IMPROVEMENTS ABOVE FROM MATERIAL AND EQUIPMENT, TYP. LOCATE AIR CONDITIONER UNIT(S) PER CODE. 21 22 23 24 1) BASIS OF ELEVATION: 6262.68 FOR THE SURVEY MONUMENT (REBAR & CAP LS 19598) MARKING THE MOST WESTERLY BUILDING ENVELOPE CORNER OF LOT 12, PER THE BENCHMARK EXHIBIT BY DRAKE CONSULTING, INC., JOB NO. 21083 DATED 12-09-2021. TOPOGRAPHY DIGITALLY SUPPLIED BY DRAKE CONSULTING ON 12-09-21, ALONG WITH AMENDED FINAL PLAT OF LOT 12, ST. FINBARR FARM SUBDIVISION DATED 12-15-21. 2) THE BOUNDARY DIMENSIONS, EASEMENTS, FLOODPLAIN, FLOODWAY LIMITS AND RIGHTS OF WAY SHOWN HEREON ARE PER THE RECORD PLAT FOR THE SUBJECT PROPERTY, LOT 12, ST. FINNBAR FARM SUBDIVISION REC. #574731, AND SURVEY CONTROL MONUMENTS FOUND AT THE TIME OF THE SURVEY, AND PLAT AMENDMENT AS SHOWN ON THE SURVEY AND AMENDMENT REFERENCED ABOVE. 3) SEE ADDITIONAL SITE NOTES, LEGEND, POINT TABLE & DETAILS ON SHEETS C2 & C3. 4) EXISTING CONTOUR INTERVAL IS 1 FT. 5) THIS (CIVIL) PLAN SET IS INTENDED TO BE PLOTTED IN COLOR. FAILURE TO DO SO MAY RESULT IN MISSING DATA & INFORMATION CRITICAL TO THE PROJECT. 10a 19082 B R U C E D LE W I SCOLORADO LICE N S E D P R O F E SSIONA L E N G INEER 4/4/22 G X X X X X X X X X X X X X X X X X X X X X X X X SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS ET C ET C ET C ET C ET C ET C ET C ET C ET C ET C ET C ET C ET C ET C ET C ET C ET C ET C ET C ET C ET C ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ETC ET C ET C ET C ET C ET C ET C G G G G G G G G G G G G G G G G G G G G G G ST. FINNBAR FARM ROAD S 1+ 0 0 2+0 0 BP: 1+00.00 PC: 1+15.52 P T : 1 + 4 5 . 7 1 P C : 2 + 0 5 . 0 4 PT: 2+25.87 62 6 4 6 2 6 3 626 2 626 1 626 0 6262 626 3 62 6 4 6 2 6 5 6263 6 2 6 3 > > > > >>>>> > > > > > > > > > > > > > > > > > > > > 6263 62 6 2 62 6 2 > > > > > > > 6 2 6 2 N2 0 ° 2 4 ' 3 9 " E 10 . 2 6 ' L =1 4 8 .5 4 ',R =1 0 5 .0 0 ' Δ =8 1 .0 5 S78° 32' 1 2 " E 126.56' 6263 1 2 ' 6 2 6 3 PROPERTY LINE, TYP. ST . F I N N B A R F A R M R O A D #101 6263.09' #102 6262.77' #103 6262.64' #104 6262.93' #105 6263.23' #106 6263.44' #109 6263.51' #110 6262.85' #1116262.97' #1126262.83' #113 6262.65'#1146262.89' #115 6262.61' #116 6262.37' #117 6262.52' #118 6262.76' #119 6263.05' #120 6262.81' #121 6263.11' #122 6263.32' #123 6263.00' #124 6263.39' #126 6263.31' #163 6262.24' #164 6262.00' S5 ° 1 7 ' 2 6 " W 1 5 . 5 2 ' S48 ° 3 2 ' 2 1 " W 5 9 . 3 2 ' R=40.00' L=30.19' R=24.00' L=20.83' R = 6 . 0 0 ' L = 1 0 . 1 1 ' R =1 2 .0 0 ' L =1 9 .0 2 ' 8. 8 6 ' 3. 9 1 ' R=34.00' L=25.66' R=46.00' L=34.72' 59.3 2 ' 56.6 6 ' R=18.00' L=28.25'R=30.00' L=25.31' .00' 8.61' 16" CPP, INV. EL. 59.35 16" CPP, INV. EL. 58.32 EDGE OF EXISTING ASPHALT, TYP. 6 2 6 2 6 2 6 1 INV. EL. 60.7 INV. EL. 61.0 24 LF 12" ADS-N12 @ 1.2% 6262 2% 2% SC F S C F S C F S C F S C F SC F SCF SCF SCF SCF SCF SCF SCF SCF SCF SC F INV. EL. 61.50 6 2 6 2 > > > > > > > > EDGE OF EXISTING ASPHALT, TYP. EXISTING ELECTRIC TRANSFORMER AND TELEPHONE RISERS 4 1 11 2 33 5 8 10 11 11 19 21 22 6263 6261 EXISTING CULVERT #166 6261.50' 10a Profile: Finnbar 12 Driveway, Sta:1+00 to Sta:2+86 Scale: Vert.=5', Horiz.=10' 6255 6260 6265 6270 6255 6260 6265 6270 Pr : 6 2 6 3 . 0 9 Ex : 6 2 6 3 . 1 1+00 Pr : 6 2 6 2 . 6 8 Ex : 6 2 6 2 . 6 Pr : 6 2 6 3 . 1 8 Ex : 6 2 6 3 . 4 2+00 Pr : 6 2 6 3 . 6 8 Ex : 6 2 6 3 . 7 Pr : 6 2 6 4 . 1 7 Ex : 6 2 6 3 . 0 2+86 -2.02%1.00% 1.50% PV I S : 1 + 0 0 . 0 0 PV I E : 6 2 6 3 . 0 9 PV I S : 1 + 3 0 . 0 0 PV I E : 6 2 6 2 . 4 8 PV I S : 2 + 6 1 . 3 8 PV I E : 6 2 6 3 . 8 0 PV I S : 2 + 8 6 . 3 8 PV I E : 6 2 6 4 . 1 7 PROPOSED FINISHED GRADE, TYP. EXISTING GRADE AT DRIVEWAY CENTERLINE, TYP. MA T C H EN D R O U N D - A - B O U T Point Table Point # 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 Desc. CL CL PC CL PT CL CL PC CL PT CL Center CL End Match Match DW DW DW DW DW DW DW DW DW DW DW DW DW DW DW DW DW DW DW DW DW DW DW DW DW DW DW Elev. 6263.09' 6262.77' 6262.64' 6262.93' 6263.23' 6263.44' 6263.80' 6264.17' 6263.51' 6262.85' 6262.97' 6262.83' 6262.65' 6262.89' 6262.61' 6262.37' 6262.52' 6262.76' 6263.05' 6262.81' 6263.11' 6263.32' 6263.00' 6263.39' 6263.78' 6263.31' 6263.30' 6263.30' 6264.41' 6264.14' 6264.20' 6264.36' 6264.33' 6264.30' 6264.21' 6264.14' 6264.03' North 16105.27 16089.64 16063.52 16044.13 16024.25 16005.76 15970.25 15945.26 16103.98 16105.74 16093.15 16099.19 16090.37 16089.26 16072.68 16078.11 16068.02 16059.03 16039.64 16048.63 16028.74 16021.51 16018.54 16013.95 15996.12 16006.37 15990.35 15969.72 15959.43 15983.00 15980.86 15978.94 15979.00 15979.71 15982.81 15988.57 15994.34 East 22653.36 22651.92 22638.59 22616.64 22594.13 22586.02 22586.77 22587.29 22671.49 22640.66 22658.27 22646.77 22645.96 22657.91 22653.12 22642.42 22634.61 22642.56 22620.61 22612.67 22590.16 22600.10 22582.65 22595.02 22598.51 22580.02 22571.91 22561.77 22609.31 22610.07 22612.55 22619.32 22622.17 22625.99 22634.56 22638.51 22638.39 Point Table Point # 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 Desc. DW DW DW DW DW DW DW DW DW, LP DW DW DW DW DW DW DW Bldg. Cor. Bldg. Cor. Bldg. Cor. Bldg. Cor. Bldg. Cor. Bldg. Cor. Swale Swale Swale Swale Swale Inv. In Inv. Out Swale Swale Swale Swale Swale Swale Swale Elev. 6264.03' 6265.00' 6265.00' 6264.69' 6264.55' 6264.48' 6264.44' 6263.64' 6263.24' 6264.02' 6263.60' 6263.90' 6263.72' 6264.32' 6264.49' 6264.46' 0.00' 0.00' 0.00' 0.00' 0.00' 0.00' 6263.00' 6262.81' 6262.54' 6262.24' 6262.00' 6262.30' 6261.50' 6264.00' 6263.63' 6263.36' 6263.00' 6262.69' 6262.32' 6262.00' North 15994.90 15946.41 15945.52 15958.99 15962.90 15962.83 15962.56 15954.21 15982.22 15965.02 15975.09 15975.13 15965.02 15970.80 15971.90 15971.35 15963.83 15937.38 15946.88 15946.04 15854.06 15860.76 15948.24 15972.09 15995.50 16007.66 16015.82 15936.54 16007.31 15903.20 15895.98 15879.88 15842.06 15819.22 15816.71 15822.44 East 22665.14 22666.16 22622.17 22621.88 22617.80 22614.59 22612.93 22567.59 22564.82 22594.09 22579.18 22594.33 22579.44 22612.76 22665.62 22639.19 22687.51 22688.06 22664.15 22624.13 22645.84 22539.80 22732.11 22726.88 22700.40 22662.64 22632.35 22607.52 22571.41 22728.95 22690.18 22666.72 22660.48 22623.32 22571.29 22526.59 00 10'20' Scale: 1" = 10' NORTH By Re v i s i o n No . Da t e 923 Cooper Ave., Ste. 201 Glenwood Springs, CO 81601 (T) 970.945.5252 www.bu-inc.com Engineer or Surveyor Seal Sheet Client Information: PROJECT NO. File Name: Designer: Drafter: Date: N: \ P R O J E C T S \ 2 0 2 1 \ 2 1 0 3 1 - L o t 1 2 S t . F i n n b a r F a r m s \ d w g \ S P - 0 2 2 1 0 3 1 L 1 2 F i n n b a r . d w g 4/ 4 / 2 0 2 2 3 : 4 4 P M Subsurface Utility Engineering (SUE) Required Project: If "Yes", SUE Certification by: Firm: Job #: Date: 9.8.7.6.5.4.3.2. 11/23/21 BUI PAH sp-02 21031 l12 finnbar.dwg 21031 619 546-0006 SAN DIEGO, CA 92101 ---- SCOTT WHITE GA R F I E L D C O U N T Y , C O L O R A D O 1. Pe r m i t 4 / 4 / 2 2 Dr i v e w a y P l a n a n d P r o f i l e Wh i t e R e s i d e n c e , L o t 1 2 , S t . F i n n b a r F a r m S u b d i v . C2 ### ###### ###### ###### MATCH TO SHEET C1 8020 8018 80188020 >>>> ETC ETC WS WS WS WS WS SL SL SL SL SL PROPOSED SPOT ELEVATION DRAINAGE SWALE DRAINAGE FLOW ARROW WATER SERVICE SEWER SERVICE ELECTRIC, TELEPHONE, COMMUNICATION SVC. GAS SERVICE SEDIMENT CONTROL FENCE PROPOSED MAJOR/MINOR CONTOUR EXISTING MAJOR/MINOR CONTOUR EROSION BALES ASPHALT DRIVEWAY & AUTO-COURT NORTH AMERICAN GREEN SC-250BN EROSION CONTROL FABRIC, OR RIPRAP ALTERNATIVE FLAGNOTE BOULDER WALL WATER CURB STOP SCF SCF TOP OF WALL BOTTOM OF WALL GRADE BREAK HIGH POINT LOW POINT TOP OF CURB TW BW GB HP LP TC 96.75 G G 1 2 3 4 5 8 10 11 19 FLAGNOTES: MATCH TO EXISTING EDGE OF ROADWAY. INSTALL 12" STORM DRAIN. PROVIDE END WALLS AND WING WALLS CONSTRUCTED WITH STONE TO MATCH BUILDING MATERIALS, OR FLARED END SECTIONS. REGRADE PORTION OF ROADSIDE DITCH AS NECESSARY TO ENABLE NEW CULVERT TO MAINTAIN 12" OF COVER AT THE DRIVEWAY. INSTALL NORTH AMERICAN GREEN SC250 EROSION FABRIC IN DISTURBED PORTION OF DITCH. TRANSITION FROM ROADWAY GRADE INTO 2% CROSS SLOPE DRAINING TOWARD THE WEST IN THE FIRST 20 FEET OF DRIVEWAY. PROPOSED ASPHALT DRIVEWAY, AUTO-COURT AND CONCRETE WALKWAYS. SEE DRIVEWAY DETAIL ON SHEET C3. CLEAN DITCH AS NECESSARY TO MAINTAIN DRAINAGE FLOWS. PROVIDE DRAINAGE SWALE AND EXTEND AS NECESSARY TO DAYLIGHT, SEE DETAIL. PROVIDE DRAINAGE SWALE AND EXTEND TO ROADSIDE DITCH. REMOVE FENCE AS NECESSARY. ALTERNATE 1). ELECTRIC, TELEPHONE & CABLE TV SERVICES ARE AS SHOWN ON THE SURVEY REFERENCED ON SHEET C1. POTHOLE NEAR THE SOUTH EDGE OF THE ROAD TO SEE IF THESE SERVICES EXIST. IF SO, EXTEND SERVICES TO UTILITY METERS. MAINTAIN COVER & CLEARANCES BETWEEN/OVER NEW SERVICES PER UTILITY REGULATIONS. EROSION LOGS, TYP. PER DETAIL ON SHEET C2. SEDIMENT CONTROL FENCE PER DETAIL ON SHEET C2. 21 22 10a 19082 B R U C E D LE W I SCOLORADO LICE N S E D P R O F E SSIONA L E N G INEER 4/4/22 00 10'20' Scale: 1" = 10' NORTH By Re v i s i o n No . Da t e 923 Cooper Ave., Ste. 201 Glenwood Springs, CO 81601 (T) 970.945.5252 www.bu-inc.com Engineer or Surveyor Seal Sheet Client Information: PROJECT NO. File Name: Designer: Drafter: Date: N: \ P R O J E C T S \ 2 0 2 1 \ 2 1 0 3 1 - L o t 1 2 S t . F i n n b a r F a r m s \ d w g \ S P - 0 2 2 1 0 3 1 L 1 2 F i n n b a r . d w g 4/ 4 / 2 0 2 2 3 : 4 4 P M Subsurface Utility Engineering (SUE) Required Project: If "Yes", SUE Certification by: Firm: Job #: Date: 9.8.7.6.5.4.3.2. 11/23/21 BUI PAH sp-02 21031 l12 finnbar.dwg 21031 619 546-0006 SAN DIEGO, CA 92101 ---- SCOTT WHITE GA R F I E L D C O U N T Y , C O L O R A D O 1. Pe r m i t 4 / 4 / 2 2 No t e s a n d D e t a i l s Wh i t e R e s i d e n c e , L o t 1 2 , S t . F i n n b a r F a r m S u b d i v . C3 ### ###### ###### ###### 4"Ø ADS TO SCH. 40 PVC 90° BEND SLOPE AT 2% MIN. TO OUTLET POINT BU I L D I N G DO W N S P O U T ALL JOINTS TO BE WATER TIGHT, TYP. TEE/BENDS WITH GLUED JOINTS OR WATERTIGHT ADAPTERS FO U N D A T I O N Scale: N.T.S. Typical Roof Drain FL O W FL O W POINTS A MUST BE HIGHER THAN POINT B D D POINT A ENTRENCH 3" POINT A POINT B POINT A EROSION LOG POINT B FLOW POINT A PLAN VIEW PLAN VIEW A A EROSION LOG SEDIMENT REMOVAL SHALL BE PERFORMED CONTINUOUSLY FOR PROPER FUNCTION.Ø ENTRENCH 3" ØFLO W TO E A C H O T H E R AP P R O X . 9 0 ° SECTION A-A AREA DRAIN SECTION D-D EROSION LOG Scale: N.T.S. Temporary Erosion Control Logs 10' MAX.24" MIN. 42" MIN. 18" MIN. 24" MIN.FLOW FLO W ANCHORED IN TRENCH AND FIRMLY ATTACHED SILT FENCE FABRIC TO POST POST (2" X 2" NOMINAL) 6" x 6" TRENCH SILT FENCE FABRIC ANCHORED IN 6"x6" TRENCH AND ATTACHED FIRMLY TO POST SILT FABRIC STAPLED TO POSTS COMPACTED BACKFILL Scale: N.T.S. Temporary Sediment Control Fence FEATURE THAT NEEDS PROTECTION USE 2 PINE STAKES 1 1/2" x 1 1/2" x 12" AT ALL EROSION LOG ENDS OR JOINTS, OTHERWISE USE A STAKE EVERY 24 IN. AND CONTINUE TO ALTERNATE ORIENTATION THROUGHOUT THE LENGTH OF THE EROSION LOG. X 1 12 " M I N . ADJACENT GRADE 4" COMPACTED ON-SITE SILT OR CLAY MATERIAL Scale: N.T.S. Drainage Swale SIDE SLOPES ADJACENT TO BUILDINGS SHALL BE 10:1 MIN. FOR 10-FEET. OTHERWISE, SIDE SLOPES SHALL BE 3:1 MIN., OR PER PLAN. LINE ALL SWALES WITH FLOWLINE GRADES EXCEEDING 6% WITH NORTH AMERICAN GREEN SC250 EROSION FABRIC OR 6"Ø NOMINAL RIPRAP. NOTE: 1.SEE THE GRADING, DRAINAGE AND EROSION CONTROL SHEET FOR SWALE LOCATIONS. 2.V-CHANNEL OR TRAPEZOIDAL CHANNEL AS SHOWN ON THE PLAN. 4"Ø SCH.40 OR SDR35 PVC RISER DOWNSPOUT FITTING OR IF DOWNSPOUT IS TOO LARGE, USE A 12" SQUARE NYLOPLAST INLINE DRAIN GRATE W/ A HOLE CUT IN GRATE TO MATCH THE DOWNSPOUT AND SLEEVE THE DOWNSPOUT/CHAIN AT LEAST 6" INTO THE PIPE. EROSION CONTROL NOTES: 1.IMPLEMENTATION OF THE EROSION AND SEDIMENT CONTROL MEASURES SHALL PRECEDE STRIPPING OF NATIVE VEGETATIVE COVER AND AS GRADING PROGRESSES. 2.ALL TEMPORARY AND PERMANENT SOIL EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE MAINTAINED AND REPAIRED AS NEEDED TO ASSURE CONTINUED PERFORMANCE OF THEIR INTENDED FUNCTION. STRAW BALE DIKES OR SILT FENCING MAY REQUIRE PERIODIC REPLACEMENT. SEDIMENT TRAPS WILL REQUIRE PERIODIC SEDIMENT REMOVAL. GENERAL NOTES: 1.ALL CONSTRUCTION SHALL MEET OR EXCEED THE CURRENT CONSTRUCTION AND DESIGN STANDARDS ESTABLISHED BY THE DESIGN GUIDELINES AND GARFIELD COUNTY AND BE SUBJECT TO OBSERVATION BY THE COUNTY AND THE PROJECT ENGINEER. IN THE EVENT OF CONFLICT PUD GUIDELINES SUPERCEDE COUNTY. 2.THIS DESIGN WAS PREPARED WITHOUT THE BENEFIT OF A SUBSURFACE UTILITY ENGINEERING (SUE) STUDY OR MAP. THIS DESIGN HAS BEEN PREPARED FOR A PRIVATE DEVELOPMENT USING EXISTING UTILITY INFORMATION PROVIDED BY OTHERS. EXISTING UTILITIES ARE SHOWN AS THEY ARE BELIEVED TO EXIST, BUT MAY NOT REPRESENT ACTUAL FIELD CONDITIONS. BOUNDARIES UNLIMITED INC. DID NOT CONFIRM ANY DATA PROVIDED OR PERFORM ANY ADDITIONAL RESEARCH OR NOTIFICATION TO ELEVATE THESE PLANS TO SENATE BILL 18-167 STANDARDS. AS SUCH, BOUNDARIES UNLIMITED INC. MAKES NO GUARANTY, EXPRESSED OR IMPLIED, FOR THE LOCATION OF SUBSURFACE UTILITIES CONTAINED WITHIN THIS PLAN SET. IF THE CLIENT AND/OR CONTRACTOR REQUIRES A SUBSURFACE UTILITY ENGINEERING STUDY OR MAP FOR FULL COMPLIANCE WITH SENATE BILL 18-167, THEN A MORE EXHAUSTIVE INVESTIGATION SHALL BE OBTAINED BY THE CLIENT AND/OR CONTRACTOR PRIOR TO COMMENCING WITH ANY CONSTRUCTION. OTHERWISE, PRIOR TO ANY EXCAVATION, CONTRACTOR SHALL CONTACT ALL APPROPRIATE UTILITY COMPANIES FOR LINE LOCATIONS. CONTRACTOR SHALL NOTIFY PROJECT ENGINEER OF ANY POTENTIAL CONFLICTS PRIOR TO UTILITY CONSTRUCTION SO THAT LINE OR GRADE CHANGES CAN BE MADE TO AVOID A CONFLICT WITH ANY EXISTING UTILITY. THE CONTRACTOR SHALL PROTECT ALL EXISTING UTILITIES FROM DAMAGE DURING CONSTRUCTION AND, AT NO EXPENSE TO THE CLIENT OR PROJECT ENGINEER, REPAIR ANY DAMAGED UTILITIES. 3.ALL EXCAVATIONS FOR UTILITY LINES, RETAINING WALLS, ROADWAYS, BUILDING STRUCTURES, DRAINAGE FACILITIES AND TRENCHES, SHALL MEET THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), COLORADO INDUSTRIAL COMMISSION, OR THE COLORADO DIVISION OF MINES, WHICH EVER APPLIES. SAFETY IS THE CONTRACTOR'S RESPONSIBILITY. NO OTHER PARTIES ARE RESPONSIBLE FOR SAFETY IN, ON OR ABOUT THE SITE, NOR FOR COMPLIANCE BY THE APPROPRIATE PARTY WITH ANY REGULATIONS RELATING HERETO. 4.COMPACTION MUST BE ATTAINED AND COMPACTION RESULTS SUBMITTED TO THE COUNTY AND THE PROJECT ENGINEER PRIOR TO ACCEPTANCE. COMPACTION SHALL MEET OR EXCEED COUNTY REGULATIONS. 95% STANDARD PROCTOR DENSITY IS REQUIRED FOR ALL ROADWAY AND DRIVEWAY SUBGRADE CONSTRUCTION AND TRENCH BACKFILL UNDER THE SAME, & 90% STANDARD PROCTOR DENSITY IN LANDSCAPE AREAS, UNLESS NOTED OTHERWISE OR AS DIRECTED BY THE GEOTECHNICAL ENGINEER. SEE SOILS REPORT FOR STRUCTURAL FOUNDATION RECOMMENDATIONS. 5.THE CONTRACTOR SHALL CONTAIN HIS CONSTRUCTION ACTIVITIES TO THE AREA WITHIN THE STREET RIGHT OF WAY AND PROPERTY OWNED, OR EASEMENTS PROVIDED TO OWNER. THE CONTRACTOR SHALL NOT OPERATE OUTSIDE THIS AREA WITHOUT THE PRIOR CONSENT OF THE PROPERTY OWNER INVOLVED. ANY DAMAGE TO PRIVATE PROPERTY BY THE CONTRACTOR OUTSIDE THESE LIMITS WITHOUT THE PERMISSION OF THE PRIVATE PROPERTY OWNER WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 6.THE CONTRACTOR SHALL ENSURE DRAINAGE AWAY FROM ALL STRUCTURES IN ALL DIRECTIONS. DO NOT ALLOW WATER TO POND ON-SITE. PROVIDE SWALES TO DRAINAGE STRUCTURES AND RUNOUT. SHALLOW DRAINAGE SWALES HAVE A TENDENCY OVER TIME TO FILL IN & BECOME LESS EFFECTIVE. PERIODIC MAINTENANCE, AT LEAST TWICE A YEAR, IS NECESSARY TO CHECK THE INTEGRITY OF THE SWALE & MAINTAIN DRAINAGE CHARACTERISTICS. BUILDING FOUNDATION WALL HEIGHT TO BE A MINIMUM OF 6" ABOVE FINISH GROUND AT EXTERIOR WALL. 7.THE CONTRACTOR SHALL AT ALL TIMES KEEP TWO FULL SETS OF CONTRACT DRAWINGS MARKED UP TO INDICATE THE AS-BUILT CONDITIONS. THE DRAWINGS SHALL BE PROVIDED TO THE OWNER AND THE ENGINEER UPON COMPLETION OF THE WORK. WHERE PRACTICAL, THE CONTRACTOR IS TO PROVIDE AT LEAST TWO TIES FROM PHYSICAL MONUMENTS TO ALL FITTINGS, VALVES, MANHOLES, AND THE END OF ALL SERVICE LINES. 8.ON-SITE OBSERVATIONS AND REVIEW CONDUCTED BY THE COUNTY OR THE PROJECT ENGINEER OF CONSTRUCTION WORK IN PROGRESS ARE NOT TO BE CONSTRUED AS A GUARANTEE OR WARRANTY BY THE COUNTY OR THE PROJECT ENGINEER OF THE COMPLETED WORK AND THE CONTRACTOR'S RESPONSIBILITIES. 9.THE CONTRACTOR SHALL TAKE ALL APPROPRIATE PRECAUTIONS TO SIGNIFICANTLY REDUCE ANY POTENTIAL POLLUTION CAUSED BY HIS ACTIVITIES, INCLUDING VEHICLE FUELING, STORAGE OF FERTILIZERS OR CHEMICALS, ETC. THE CONTRACTOR SHALL HAVE IDENTIFIED PROCEDURES FOR HANDLING POTENTIAL POLLUTANTS AND IDENTIFIED SPILL PREVENTION AND RESPONSE PROCEDURES PRIOR TO ANY ACTIVITIES AT THE PROJECT SITE. 10.THE CONTRACTOR SHALL NOT SCALE DRAWINGS FOR CONSTRUCTION PURPOSES. ANY MISSING DIMENSIONS OR DISCREPANCIES IN PLANS, FIELD STAKING, OR PHYSICAL FEATURES SHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ENGINEER. IF THE CONTRACTOR PROCEEDS WITH THE WORK WITHOUT NOTIFYING THE ENGINEER, HE DOES SO AT HIS OWN RISK. 11.DISPOSAL OF TRASH, ASPHALT, CONCRETE AND CONSTRUCTION DEBRIS IS THE CONTRACTORS RESPONSIBILITY AND SHALL BE CONSIDERED PART OF THE WORK. 12.HORIZONTAL & VERTICAL INFORMATION FOR EXISTING PROPERTY LINES, TOPOGRAPHY, ROADWAY, UTILITIES & DRAINAGE STRUCTURES WERE SUPPLIED BY DRAKE CONSULTING, INC., JOB NO. 21083 DATED 12-09-2021. SEE LANDSCAPE, ARCHITECTURAL AND STRUCTURAL ENGINEERING PLANS FOR ADDITIONAL BUILDING AND LANDSCAPE INFORMATION. 13.SEE ADDITIONAL LANDSCAPE INFORMATION FROM STAN CLAUSON & ASSOCIATES INC. IN NON HARDSCAPE AREAS, GRADE AT A MINIMUM OF 12" IN THE FIRST 10 FEET AWAY FROM THE STRUCTURE, OR AS DIRECTED BY THE GEOTECHNICAL STUDY. EXTERIOR BACKFILL SHOULD BE ADJUSTED TO NEAR OPTIMUM MOISTURE AND COMPACTED TO AT LEAST 95% OF THE MAXIMUM STANDARD PROCTOR DENSITY IN PAVEMENT AREAS AND TO AT LEAST 90% OF THE MAXIMUM STANDARD PROCTOR DENSITY IN LANDSCAPE AREAS. SEE & FOLLOW RECOMMENDATIONS OF THE GEOTECHNICAL SUBSOIL STUDY BY HEPWORTH-PAWLAK GEOTECHNICAL, INC. DATED 08-04-1998, JOB NO. 198 483. 14.ALL PRODUCT INFORMATION SHOWN IS AS PROVIDED BY THE MANUFACTURER. THE CONTRACTOR IS RESPONSIBLE FOR REVIEWING AND COMPLYING WITH THE MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS FOR THE INSTALLATION OF ALL MATERIALS WITH SPECIAL ATTENTION TO PROPER SEALING OF MATING SURFACES. THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE ENGINEER IF ANY DISCREPANCIES ARE FOUND BETWEEN THE DELIVERED PRODUCTS AND THOSE SHOWN ON THIS PLAN. 15.FOUNDATION AND RETAINING WALL DESIGNS TO BE OBTAINED FROM, OR VERIFIED BY THE PROJECT STRUCTURAL OR GEOTECHNICAL ENGINEER. 16.THE FOUNDATION DRAIN SYSTEM SHALL BE INSTALLED PER THE RECOMMENDATION OF THE STRUCTURAL AND GEOTECHNICAL ENGINEERS. 17.THE SURVEYOR RESPONSIBLE FOR STAKING THE FOUNDATION OF THE HOUSE IS RESPONSIBLE TO MAKE SURE HE HAS THE LATEST SITE, FOUNDATION & ARCHITECTURAL PLANS AVAILABLE, ALONG WITH ANY UPDATED LOTLINE, SETBACK & EASEMENT INFORMATION. 18.INSTALL ROOF GUTTERS AND DOWNSPOUTS THAT DISCHARGE WELL BEYOND THE LIMITS OF ALL BACKFILL. CONFIRM DOWNSPOUT DRAINAGE HAS GOOD POSITIVE GRADE RUNNING AWAY FROM THE HOUSE. STORM DRAIN PIPES TO BE INSTALLED WITH 1% MINIMUM SLOPE TO THE OUTFALL POINTS. HEAT TAPE SHALL BE INSTALLED IN ALL EXTERIOR ROOF GUTTERS, DRAIN PIPES, DOWNSPOUTS, AREA DRAINS, TRENCH DRAINS, STORM DRAIN PIPES AND GRATED STRUCTURES. 19.LANDSCAPING WHICH REQUIRES REGULAR HEAVY IRRIGATION SUCH AS SOD, AND LAWN SPRINKLER HEADS SHOULD BE LOCATED AT LEAST 10 FEET FROM FOUNDATION WALLS. 20.ACCUMULATED SNOWFALL SHALL BE REMOVED TO GRASS AREA TO ENSURE THAT PROPER DRAINAGE AWAY FROM THE BUILDING IS MAINTAINED. 21.FINISH GRADE & SPOT ELEVATIONS AT THE EXTERIOR OF THE STRUCTURE ASSUME THAT THE FOUNDATION WALLS EXTEND ABOVE THE BUILDING FINISH FLOOR & HANGER FLOOR JOISTS ARE USED. EXTERIOR GRADE TO BE A MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL. THE FOUNDATION WALL HEIGHT MAY NEED TO BE EXTENDED IN ORDER TO ACHIEVE POSITIVE DRAINAGE AWAY FROM THE STRUCTURE. 22.INSTALL DEEP & SHALLOW UTILITY SERVICES ACCORDING TO RESPECTIVE UTILITY COMPANY OR METRO DISTRICT SPECIFICATIONS AND REGULATIONS. HORIZONTAL LOCATIONS OF SERVICE LINES ARE SUGGESTIONS ONLY, PROPOSED UTILITY SERVICES TO THE RESIDENCE MAY BE VARIED FROM THE LOCATIONS SHOWN. ALL WATER AND SEWER SERVICES SHALL BE INSTALLED PER METRO DISTRICT REGULATIONS. 23.DRAINAGE PIPES CALLED OUT AS ADS SHALL BE ADVANCED DRAINAGE SYSTEMS N-12 WATER RESISTANT PIPE (ADS N-12-WT) OR ENGINEER APPROVED EQUAL. ALL PIPES SHALL BE INSTALLED WITH WATERTIGHT CONNECTIONS. 24.CONTRACTOR IS RESPONSIBLE TO OBTAIN ALL NECESSARY PERMITTING FOR CONSTRUCTION FROM THE APPROPRIATE GOVERNMENTAL ENTITIES. 25.ALL UTILITIES, BOTH UNDERGROUND OR OVERHEAD, SHALL BE MAINTAINED IN CONTINUOUS SERVICE THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD. THE CONTRACTOR SHALL BE RESPONSIBLE AND LIABLE FOR DAMAGES TO, OR INTERRUPTION OF, SERVICES CAUSED BY THE CONSTRUCTION. Scale: N.T.S. General Notes PAVEMENT SECTION NOTE: 1.ALL AGGREGATE & SUBGRADE MATERIAL SHALL BE COMPACTED TO 95% STANDARD PROCTOR AT A MOISTURE CONTENT WITHIN 2% OF OPTIMUM. 2.IN NEW PAVING LOCATIONS STRIP ALL TOPSOIL, SCARIFY AND RECOMPACT SUBGRADE A MINIMUM OF 12" DEPTH TO 95% STANDARD PROCTOR. 3.EXTEND THE SECOND TIER (12" CLASS 2 ROAD BASE, OR 8" CLASS 6 ROAD BASE) 1 FT. BEYOND EDGE OF PAVEMENT OR GRAVEL SURFACE, BOTH SIDES. CONTRACTOR TO VERIFY WITH PROJECT GEOTECHNICAL CONSULTANT. DRIVEWAY & AUTOCOURT SECTION 3" CLASS C ASPHALTIC PAVEMENT 8" CLASS 6 ABC 12" SUBGRADE (SCARIFY & RECOMPACT) ASPHALT PAVEMENT SECTION 2nd TIER CLASS 6 AGGREGATE BASE COURSE COMPACTED TO 95% STANDARD PROCTOR 12' DRIVEWAY 1.0'1.0 GRAVEL SHOULDER 2 MAX. 1 2.0% STRIP ALL TOPSOIL, SCARIFY AND RECOMPACT SUBGRADE A MINIMUM OF 12" DEPTH TO 95% STANDARD PROCTOR PAVEMENT EXISTING GROUND CL 2.0% 2 MAX. 1 EROSION CONTROL FABRIC 1 FT. DRAINAGE DITCH IF SHOWN IN PLAN VIEW GRAVEL SHOULDER PROPOSED DRIVEWAY TYP. SECTION TO BE VERIFIED BY PROJECT GEOTECHNICAL ENGINEER 19082 B R U C E D LE W I SCOLORADO LICE N S E D P R O F E SSIONA L E N G INEER 4/4/22